Fire Riser Rooms

Below you can find two pictures showing fire riser rooms at a multi-storey building.

Picture 1 - Fire Riser Room


=================
RELATED ARTICLES: Building’s electrical rooms layout Substation rooms layout diagram |  1600 kVA Transformer Pictures | Cable ladder pictures  | Electrical installation pictures |
=================

Here you can see wet riser pipes and hose reel pipes.

For the uninitiated, wet risers are vertical pipes that are always under pressure with water.

This means that any time a fire occurs in a building, you will have water to fight the fire immediately. You can connect the flexible hose provided in the riser room or the riser shaft at each floor to the landing valve of the vertical wet riser pipe.

The hose reel system is also part of the fire fighting system in a building.

To be precise, this is what you can and will use to fight fire when it happens. The wet riser are designed for use by firemen.

The hose reel pipes are also kept under pressure at all time. The system are provided with pumps that operates automatically to keep the hose reel piping under adequate constant pressure at all times.

The water jet produced by the hose reels are however only adequate to fight small fires. That is why firemen will not use it. It is designed for use by building occupants BEFORE firemen arrives.

Dry risers, on the other hand, are similar to the wet riser piping, but without the water. They are simply vertical pipes without water. The water needed to fight fire will be from the fire trucks brought in by the firemen when they arrive.

The above is a highly simplified brief of the fire risers to give casual readers some meaning of what they are.

I will post a more detailed explanation of the fire fighting systems for buildings in a near future.

Picture 2 - Chilled water pipe installed inside a fire riser shaft.


Here you can see a vertical  pipe that may not belong here.

This is a chilled water pipe.

Some fire authorities may not allow other services to be installed inside the fire riser shaft. It was allowed in this project.

Copyright http://electricalinstallationwiringpicture.blogspot.com Fire Riser Rooms

Monday, January 21, 2013

Architectural Lighting

I do not know how many readers will like this picture, but I like it.

Picture 1 - A nice picture



================ RELATED ARTICLES: Compound Lighting Installation Pictures |  Electric Cable Drum Pictures | Underground street light cables | Compound lighting storage yard | Feeder pillar single line diagram | Bollard light pictures | Feeder pillar hazard pictures  | Compound lighting foundation size  | Electrical installation pictures |  Temporary lighting installation pictures
================


A few may even question whether it does qualify into the category of electrical pictures.

This is actually a photoshot of the top of a bridge at night. The bridge shines out nicely as it reflects the light rays from light sources installed at ground level.

It is true that this is actually an architectural work.. architectural lighting to be precise.

However, the architects need electrical engineers to to handle these high power lighting, especially since the lighting is actually installed at public areas.

Picture 2 - One of the light sources at ground level.






I have been silent for many months from this blog. Today I am coming back.

I however have not decided yet what themes I am going to use to upload pictures this time. So I decided that I should start slow and use whatevers pictures that I can snap around me.

That is why I show you this picture.

The are a number of nice bridges here and I can try to take a few shots.

See you in the next post.

Copyright http://electricalinstallationwiringpicture.blogspot.com Architectural Lighting